The effect of transverse reinforcement arrangement on the flexural capacity of short columns using nonlinear numerical analysis
The effect of transverse reinforcement arrangement on the flexural capacity of short columns using nonlinear numerical analysis
S. Mohamad S. Kolbadi1 MohamadReza Bagheri2
1) Assistance Professor, Department of Civil Engineering, Technical and Vocational University (TVU), Tehran, Iran.
2) Department of Civil Engineering, Technical and Vocational University (TVU), Tehran, Iran.
IOI Code
:
AACZ-ABGFFK
Publication :
The 5th International Conference on Seismic Retrofitting(5icst.ir)
Abstract :
The presence of short columns in concrete buildings, at least around stairwells, is natural and unavoidable. The absorption of large shear forces due to the short height of these columns (low shear span-to-depth ratio) is the most important factor in the weakness of short columns. To improve their performance, it is necessary to provide appropriate ductility with the possibility of creating flexural plastic hinges through shear strengthening of these members. Therefore, their strengthening and retrofitting are of particular importance. Shear failure is among the undesirable failure modes that typically begins with the formation of diagonal cracks in the column, followed by rupture or opening of transverse reinforcement, buckling of longitudinal reinforcement, and ultimately ends in sudden and brittle failure of the column. This means that the seismic performance of specimens strengthened with the truss arrangement is approximately 1.4 times that of the typical condition.
Keywords : energy dissipation short column finite element model extremum stress envelope