Performance Assessment of BRB Inverted-V Bracing Systems with Zipper Columns under Sequential Earthquakes
Performance Assessment of BRB Inverted-V Bracing Systems with Zipper Columns under Sequential Earthquakes
Mahmoud Goli1 Sina Dehyadegari2 Ali Masoumi3 Hamid Keykhah4 Tohid Akrami5 Matin Morovati6
1) M.Sc. in Earthquake Engineering, Sadra University, Tehran, Iran,
2) PhD Candidate in Structural Engineering, Shahrood University of Technology, Shahrood, Iran
3) PhD student in Structural Engineering, Qom University, Qom, Iran
4) PhD student in Structural Engineering, Islamic Azad University, Dezful Branch, Iran
5) M.Sc. in Earthquake Engineering, Urmia University of Technology, Urmia, Iran
6) M.Sc. Student, Department of Civil Engineering, K. N. Toosi University of Technology, Tehran, Iran
IOI Code
:
AADK-ABBZDC
Publication :
3rd International Congress on Science, engineering & New Technologies(secongress.com/3rd)
Abstract :
Due to the continuous decrease in global energy resources, the science of structural retrofitting has become one of the most important research fields in structural engineering. Retrofitting is considered a practical and economical solution to improve the performance of existing deficient buildings without the need for demolition and reconstruction, thereby saving time, cost, and energy. In this study, considering the wide application of concentrically braced frame (CBF) systems in Iran, the seismic retrofitting of buildings with this structural system is investigated using the zipper column concept. The use of zipper columns in chevron (inverted-V) bracing systems improves the well-known weakness of chevron-braced frames, namely local buckling and yielding concentration in beams, which results in excessive lateral deformations.
To evaluate the seismic performance improvement, three buildings with 5, 10, and 15 stories were modeled and analyzed under three earthquake ground-motion records using nonlinear time-history analysis in SAP2000. The results indicate the poor seismic performance of the original braced frames compared to the retrofitted systems. Implementation of the zipper column significantly reduced plastic hinge formation and inter-story drifts, improved performance levels, and enhanced the energy dissipation capacity of the structures under earthquake loading. Overall, the retrofitted systems exhibited more stable and desirable seismic behavior
Keywords : zipper column nonlinear time history analysis structural energy dissipation lateral displacement buckling restrained braced frames