Dynamic Simulation of a Thermal Mass Flowmeter.
Dynamic Simulation of a Thermal Mass Flowmeter.
Afshin Kadivaryan.1 Maryam Gholipour.2
1) 1. Department of Electrical Engineering, IAUT, Science and Research Branch, Tehran,
2) 2. Department of Electrical Engineering, Islamic Azad University, Qazvin Branch, Iran,
IOI Code
:
AAGF-ABBEKF
Publication :
9th International Conference on Applied Researches in Science & Engineering (carseconf.com/9th)
Abstract :
Thermal mass flowmeters are widely used for measuring the mass flow rate of gases in the oil, gas, and process industries. These flowmeters operate based on heat transfer from a heated sensor to the flowing fluid, where the electrical power required to maintain the sensor temperature depends on the fluid’s mass flow rate. In this study, a dynamic model of a thermal mass flowmeter is developed and numerically simulated in MATLAB. The effects of measurement noise, sensor bias, and thermal disturbances on sensor response and mass flow estimation are analyzed. Additionally, the use of a Kalman filter is investigated to improve estimation accuracy. The results show that noise introduces random fluctuations, bias causes systematic error, and thermal disturbances reduce measurement accuracy. Applying a Kalman filter stabilizes and improves the precision of mass flow estimation.
Keywords : dynamic simulation thermal mass flowmeter