Reduced-Order Screening of a Microperforated Backing-Cavity Module for Frequency Shaping in a Stethoscope Chestpiece
Reduced-Order Screening of a Microperforated Backing-Cavity Module for Frequency Shaping in a Stethoscope Chestpiece
Arada Sarkisian1
1) Tehran University of Medical Sciences - Email:
IOI Code
:
ABEB-ACAZKE
Publication :
4th International Conference on Recent Advances in Engineering, Innovation and Technology - Belgium(eitconf.com)
Abstract :
Background and Objective: Preserving the transmission of low-frequency heart sounds while attenuating higher-frequency components in a controlled manner is a potential objective in stethoscope diaphragm design. The frequency response of such a system depends not only on the diaphragm material but also on the interaction between its mechanical properties, the acoustic impedance of the coupled components, and the geometry of adjacent cavities. This study aimed to develop a conceptual design and perform computational screening of an integrated module comprising a polymer diaphragm, a microperforated panel, and a backing cavity to evaluate its potential for frequency shaping within the target range.
Methods: A reduced-order acoustic model was developed by coupling the mechanical behavior of a clamped circular polyethylene terephthalate (PET) diaphragm with the acoustic compliances of the front and backing cavities, a Maa-type microperforated-panel impedance, and the impedance of a 3-mm-diameter outlet. To examine sensitivity to loading conditions, three generic scalings of the outlet acoustic load were considered. A total of 41,040 parameter combinations were screened over a frequency range of 20–2000 Hz. Candidate configurations were initially evaluated at 10-Hz frequency increments, followed by re-evaluation at 1-Hz resolution. The system response was compared with that of an open cavity with an equivalent air volume and without a microperforated panel.
Results: Nine configurations passed the initial screening, and eight met the predefined criteria for mean response across the specified frequency bands after re-evaluation at 1-Hz resolution. The selected configuration comprised a 0.25-mm-thick PET diaphragm, a front cavity with a depth of 4 mm, a rigid microperforated panel with a thickness of 0.5 mm and twelve 0.30-mm-diameter holes, and a backing cavity with a depth of 8 mm. The estimated axial height of the assembly was 16.75 mm. Across the loading scenarios, the mean relative change in transfer level ranged from −1.36 to −0.07 dB at 20–500 Hz, from −4.97 to −4.63 dB at 501–1000 Hz, and from −3.94 to −3.73 dB at 1001–2000 Hz. However, only approximately 60–64% of the sampled frequencies in the upper bands exhibited attenuation of at least 3 dB. None of the screened candidate configurations satisfied the more stringent requirement of at least 3-dB attenuation at every frequency within the stopband under all three loading scenarios.
Conclusion: The developed model enabled parametric screening of a coupled diaphragm–microperforated panel–backing cavity structure and identified a candidate configuration for experimental evaluation. However, the current results are insufficient to establish a broadband low-pass response, improved rejection of environmental noise, or superior diagnostic performance. Experimental validation, including mechanical characterization of the diaphragm and measurement of acoustic transfer response under controlled conditions, is required to determine the actual performance of the proposed design.
Keywords : stethoscope diaphragm microperforated panel acoustic impedance reduced order model frequency response