Progressive Collapse Assessment in Pentagon-Shaped Zipper-Braced Steel Structure with Mass Irregularity

Progressive Collapse Assessment in Pentagon-Shaped Zipper-Braced Steel Structure with Mass Irregularity

Farhad Abbas Gandomkar1

1) PhD in Civil engineering, Structural engineering, Faculty staff, Jundi-Shapur University of Technology, Dezful, Iran.

IOI Code : ABFG-ACAFHK
Publication : 12th.international Congress on Civil Engineering, Architecture, Art and Urban Development(12icsau.ir)
Abstract :
    This paper aims to investigate the progressive collapse behavior of steel structures with a pentagonal plan equipped with zipper bracing and subjected to vertical mass irregularity. Three-dimensional models with different numbers of stories and bays were initially designed in accordance with the seismic provisions of Iranian Standard No. 2800 and the National Building Regulations. The structural models were designed in ETABS using the equivalent static analysis method, considering a steel ordinary concentrically braced frame (OCBF) as the lateral load-resisting system. Subsequently, the progressive collapse performance of the structures was evaluated using the Alternate Load Path (ALP) method based on the requirements of the Iranian National Building Code. Nonlinear dynamic analyses were conducted in SAP2000 following the removal of critical columns to assess the structural response under progressive collapse scenarios. The numerical results showed that the corner column removal scenario produced the most critical response in all investigated models. Increasing the number of bays from three to five reduced the displacement response by approximately 10% in the 3-story frames and by 4.5–5% in the 8-story frames, demonstrating the beneficial effect of increased structural redundancy. In contrast, increasing the building height from 3 to 8 stories significantly increased the displacement response and the susceptibility to progressive collapse. The influence of mass irregularity became more pronounced in taller buildings, indicating that the vertical distribution of mass plays a significant role in progressive collapse performance. Overall, structural height, bay number, mass distribution, and the location of the removed column were identified as the governing parameters controlling progressive collapse resistance.

Keywords : progressive collapse zipper bracing mass irregularity finite element method