Comparative Performance of Horizontal and Vertical Shading Devices for Visual Comfort in Architectural Design Studios across Two Hot Climates in Iran A South-Facing Case Study of Yazd and Bandar Abbas under a Summer-Solstice Scenario
Comparative Performance of Horizontal and Vertical Shading Devices for Visual Comfort in Architectural Design Studios across Two Hot Climates in Iran A South-Facing Case Study of Yazd and Bandar Abbas under a Summer-Solstice Scenario
Zohreh Salahshoor1 Mahnaz Mahmoudi Zarandi2 Saeid Ghadimi3
1) PhD Student, Architectural Engineering, Islamic Azad University, North Tehran Branch, Iran
2) Assistant Professor, Architectural Engineering, Islamic Azad University, North Tehran Branch, Iran
3) PhD Student, Architectural Engineering, Islamic Azad University, North Tehran Branch, Iran
IOI Code
:
ABFG-ACAHKH
Publication :
12th.international Congress on Civil Engineering, Architecture, Art and Urban Development(12icsau.ir)
Abstract :
Shading devices in architectural design studios must balance useful daylight availability against discomfort glare, a particularly relevant concern in warm climates with different humidity and solar-radiation conditions. This study compares horizontal and vertical shading systems on the south-facing façade of a reference studio in Yazd (hot–dry) and Bandar Abbas (hot–humid), Iran. Twelve matched simulation records were reanalysed: two cities, two shading types and three inclination angles (15°, 30° and 45°), all from a reported summer-solstice scenario. The archived Rhino/Grasshopper–Honeybee/Radiance outputs included daylight factor (DF), daylight autonomy (DA), useful daylight illuminance (UDI), underlit and overlit UDI components, and daylight glare probability (DGP). Vertical shading preserved higher mean UDI in both cities: 62.97% versus 43.96% for horizontal shading in Yazd, and 60.41% versus 45.17% in Bandar Abbas. Increasing the angle from 15° to 45° reduced UDI by 23.89 and 24.85 percentage points for horizontal systems in Yazd and Bandar Abbas, respectively, compared with reductions of only 5.08 and 3.81 points for vertical systems. Higher-angle horizontal shades reduced DGP but markedly increased underlit conditions. All twelve recorded cases had DGP below 0.35. Among the tested alternatives, 15° vertical shades achieved the highest UDI in both cities. These findings support multi-indicator preliminary shading selection for south-facing studios, without implying annual or universal optimum conditions.
Keywords : horizontal shading vertical fins daylighting visual comfort useful daylight illuminance daylight glare probability architectural design studios yazd bandar abbas