Base Isolation in High-Seismicity Regions: A Critical Review of Implementation, Design Verification, and Lifecycle Resilience
Base Isolation in High-Seismicity Regions: A Critical Review of Implementation, Design Verification, and Lifecycle Resilience
Seyyed Amirhossein Hosseini Chaleshtori1 Mohammad Alibabaei Shahraki2
1) Department of Civil Engineering, Technical and Vocational University, Tehran, Iran
2) Department of Civil Engineering, Technical and Vocational University, Tehran, Iran
IOI Code
:
ABKD-ACZGAK
Publication :
Fourth International Conference on applied researches in civil engineering, architecture and urban planning (icarcau.com)
Abstract :
Base isolation is among the most effective earthquake-protection strategies for limiting structural and non-structural damage while supporting post-earthquake functionality. Unlike conventional seismic design, which primarily relies on ductility and controlled damage in the superstructure, base isolation modifies the dynamic response of a building by introducing a flexible and energy-dissipating interface between the structure and its foundation. This mechanism generally lengthens the fundamental period, reduces acceleration demand, and limits interstory drift; however, it transfers the governing design challenge from member strength to displacement capacity and stability at the isolation level. This paper presents a critical narrative review of base-isolation practice in high-seismicity regions, with emphasis on implemented building and retrofit applications. The review synthesizes lessons from elastomeric, friction-based, rolling, and hybrid isolation systems and examines their implications for nonlinear analysis, near-fault hazard, torsional response, device qualification, construction quality, and long-term maintenance. Evidence from hospital retrofits, heritage structures, and large-scale implementation programs indicates that isolation can substantially improve functional resilience when the isolation interface, seismic moat, non-structural components, and utility connections are designed as an integrated system. The review identifies three central conclusions. First, maximum isolator displacement, rather than base shear alone, governs the safety of isolated buildings under severe earthquakes. Second, nonlinear three-dimensional time-history analysis is essential for irregular structures and near-fault sites. Third, the long-term reliability of isolation systems depends on material aging, friction variability, inspection accessibility, and lifecycle monitoring. Future research should focus on probabilistic displacement prediction, multi-hazard assessment, durability databases, and cost-effective isolation solutions for developing seismic regions.
Keywords : base isolation seismic resilience nonlinear time history analysis elastomeric bearings friction pendulum systems