valuation of the seismic behavior of steel coupled shear walls subjected to seismic sequences

valuation of the seismic behavior of steel coupled shear walls subjected to seismic sequences

akbar sharifi1

1) M.Sc. in Civil Engineering, Structural Engineering, University of Jiroft

IOI Code : AACH-ABHAGK
Publication : 7th.International Conference & 8th.National Conference on Civil Engineering, Architecture, Art and Urban Design(8iccacs.ir)
Abstract :
    In this study, the seismic behavior of steel coupled shear walls (SCSWs) subjected to mainshock–aftershock earthquake sequences was investigated using nonlinear time-history analysis. To evaluate the effect of structural height on seismic response, three structural models with 5, 7, and 9 stories, based on the archetypes introduced in FEMA P-695, were selected and modeled in ABAQUS. All analyses were conducted under fixed-base conditions so that the inherent nonlinear behavior of the structure could be assessed without the influence of soil–structure interaction. In this research, three real earthquake sequences, namely Chi-Chi (1999), Tohoku (2011), and Kumamoto (2016), were selected from the PEER ground motion database and applied to the models after spectral matching over the period range corresponding to the structures. The main evaluation indices included interstory drift, base shear, residual drift, plastic hinge formation, and energy dissipation in coupling beams. The results showed that earthquake sequences intensify the nonlinear response and significantly increase the residual deformations in all models. In particular, the residual drift in the 9-story building reached 0.96%, which represents an increase of approximately 85% compared to the 5-story building, with a value of 0.52%. It was also observed that the 7-story building exhibited greater dynamic sensitivity to damage accumulation due to the overlap between its first-mode natural period and the dominant period of the ground motions. On the other hand, long coupling beams, owing to their higher flexural ductility, dissipated approximately 35% to 40% more energy than short coupling beams, and consequently played a more effective role in protecting the shear walls. Overall, the findings of this study highlight the necessity of considering the effects of mainshock–aftershock earthquake sequences as well as the decisive role of coupling beam characteristics in the performance-based design of steel coupled shear wall systems.

Keywords : steel coupled shear wall (scsw) nonlinear time history analysis (nltha) residual drift energy dissipation coupling beam