Investigating the Effect of Torsional Irregularity on Determining the Seismic Separation Distance Between Adjacent Buildings Using Response Spectrum Analysis
Investigating the Effect of Torsional Irregularity on Determining the Seismic Separation Distance Between Adjacent Buildings Using Response Spectrum Analysis
Vahid Molseghi1
1) Faculty Member at the Malayer Branch of Islamic Azad University Email:
IOI Code
:
AACH-ABHBZC
Publication :
7th.International Conference & 8th.National Conference on Civil Engineering, Architecture, Art and Urban Design(8iccacs.ir)
Abstract :
Pounding between adjacent buildings during earthquakes is one of the major causes of structural damage in densely built urban areas. Differences in the dynamic characteristics of neighboring buildings result in different relative displacements, and when the separation distance is insufficient, pounding occurs, potentially causing significant damage to both structural and non-structural components. In buildings with torsional irregularity, the mismatch between the center of mass and the center of stiffness induces torsional rotation in addition to lateral response, making the determination of the required seismic separation distance more complex.
The objective of this study is to investigate the effect of torsional irregularity on the required seismic separation distance between adjacent buildings using linear dynamic response spectrum analysis. For this purpose, several steel building models with different heights, including 2-, 4-, 8-, 12-, and 16-story structures, and various eccentricity ratios were analyzed. The effects of the period ratio of adjacent buildings, the degree of eccentricity, and the number of stories on the required separation distance were evaluated. The obtained results were then compared with the provisions of the Iranian Standard No. 2800 and the International Building Code (IBC).
The results indicate that the required seismic separation distance increases with increasing period ratio between adjacent buildings, increasing eccentricity, and increasing building height. Furthermore, for most of the analyzed models, the separation distances specified by the IBC were found to be more conservative than those obtained from the response spectrum analysis, while the differences decreased for structures with shorter vibration periods. The findings of this study demonstrate that, for buildings with torsional irregularity, response spectrum analysis can provide a more accurate estimation of the required safe separation distance between adjacent buildings than simplified code-based equations.
Keywords : seismic separation distance torsional irregularity response spectrum analysis adjacent buildings earthquake engineering