Assessment of the Thermal Performance of Brick Lattice Envelopes with Variable Patterns and Spacing in the Hot Semi-Arid Climate of Dezful
Assessment of the Thermal Performance of Brick Lattice Envelopes with Variable Patterns and Spacing in the Hot Semi-Arid Climate of Dezful
Kolsoom Kamkar1 Kourosh Momeni2 Akbar Mousaeijoo3
1) Department of Architecture, Ahv.C, Islamic Azad University, Ahvaz, Iran.
2) Associate Professor, Department of Architecture, Jundi-Shapur University of Technology, Dezful, Iran
3) Department of Architecture, Ahv.C, Islamic Azad University, Ahvaz, Iran.
IOI Code
:
AACZ-ABCHKD
Publication :
The 5th International Conference on Seismic Retrofitting(5icst.ir)
Abstract :
In hot semi-arid climates, controlling a building’s heat exchange through passive strategies plays a significant role in reducing energy consumption. The present study focuses on the distance between the perforated secondary brick screen and the glazed window surface, examining the effect of this variable on heating load demand. The research was conducted using a simulation-based method through the development of 12 lattice screen models in software.
The findings indicate that a 10 cm فاصله between the two layers yields the most favorable heating energy performance, whereas the poorest performance occurs at a 40 cm فاصله. Subsequently, the configurations with 20 cm and 30 cm separations from the main façade demonstrate progressively less optimal but still comparatively better performance. Therefore, modifying the فاصله between the two layers is effective in optimizing and reducing the heating load
Keywords : thermal comfort heating load perforated surfaces traditional architecture of dezful