The Paradox of Seismic Soil-Structure Interaction in Soft Soils: Dominance of Kinematic Response and Reduced Inertial Force Transfer
The Paradox of Seismic Soil-Structure Interaction in Soft Soils: Dominance of Kinematic Response and Reduced Inertial Force Transfer
behrouz faizi1 iman raeisizadeh2 marze razavi3
1) Student in Geotechnical Engineering, Afarinesh Elm Gostar Boroujerd Higher Education Institute, Boroujerd, Iran
2) Department of Civil Engineering, Faculty of Civil Engineering, National Skills University, Arak, Iran
3) Faculty Member, Faculty of Civil Engineering, Tafresh University, Tafresh, Iran
IOI Code
:
AACZ-ABGECE
Publication :
The 5th International Conference on Seismic Retrofitting(5icst.ir)
Abstract :
Conventional seismic design approaches are based on the assumption that higher ground acceleration directly leads to greater internal forces in the structure. This study reveals a fundamental paradox in soil-structure interaction (SSI) for shallow foundations on soft soils, where this assumption is completely violated. We demonstrate that in very soft soils, the amplification of kinematic response (acceleration amplification) is decoupled from the inertial force transfer to the foundation due to the shear failure of the underlying soil. To investigate this phenomenon, three soil profiles representative of Tehran’s alluvium with relative densities of 70% (S70), 85% (S85), and 95% (S95) were modeled using the advanced HS-small model in PLAXIS 2D software. A shallow foundation with a width of 2.0 meters, subjected to a static load of 100 kPa, was subjected to the Tabas earthquake record (1978).
The results indicated a stark contrast: the soft profile (S70) experienced the highest site amplification (amplification factor of 6.02, peak acceleration of 1.92g), yet the bending moment and shear force in the foundation were reduced to nearly zero due to extensive soil failure, which acted as a “geotechnical fuse.” This “protective” mechanism, however, came at the cost of a catastrophic permanent settlement of 253 mm. In contrast, the dense profile (S95), despite much lower amplification (amplification factor of 2.10, peak acceleration of 0.67g), transferred significant internal forces to the foundation while exhibiting only 33 mm of settlement. Hysteresis loop analysis confirmed that S70 dissipated seismic energy through large plastic deformations, while S95 exhibited near-elastic behavior.
These findings quantitatively prove the SSI paradox in soft soils: premature soil yielding prevents the effective transfer of inertial forces to the foundation, even though the kinematic demand is at its peak. Therefore, this research challenges conventional design assumptions and strongly states that in soft soils, the governing criterion for foundation seismic performance shifts from the foundation’s internal force-carrying capacity to the control of settlement and geotechnical stability
Keywords : soil structure interaction (ssi) soft soil seismic amplification shear failure foundation design