Behavior of steel jacketed reinforced concrete columns under axial load: Laboratory study and finite element analysis

Behavior of steel jacketed reinforced concrete columns under axial load: Laboratory study and finite element analysis

Masood Tajasm1

1) Master of Science in Civil Engineering

IOI Code : AACZ-ABGEED
Publication : The 5th International Conference on Seismic Retrofitting(5icst.ir)
Abstract :
    Reinforcement of reinforced concrete columns, as one of the most important methods for improving and increasing the load-bearing capacity of structures, has received widespread attention from researchers in recent years. Change in the use of structures, increased loads, poor initial design, structural deterioration, and the need for seismic reinforcement are among the most important reasons for using reinforced concrete column reinforcement methods. Among the various reinforcement methods, the use of steel jackets has been widely used due to its ease of implementation, significant increase in load-bearing capacity, and improved ductility of columns. In this study, the behavior of reinforced concrete columns reinforced with steel jackets under axial load was investigated experimentally and numerically. Three main parameters were studied, including the type of steel reinforcement system, the number of horizontal ties, and the dimensions of the tie plates. The experimental program included seven reinforced concrete column specimens with dimensions of 1200×200×100 mm, including two reference specimens and five reinforced specimens. Also, to analyze the behavior of the specimens, a finite element model was developed in ANSYS 12.0 software. The results showed that the use of steel jackets significantly increased the load-bearing capacity of the columns; so that the largest increase in load-bearing capacity was for the specimen reinforced with gutters and six horizontal ties, which showed an increase of about 47 percent compared to the reference specimen. The results also showed that increasing the number of restraints in gutter-based systems has a greater effect than in corner-based systems. Comparison of laboratory results and finite element analysis also showed a good agreement between the numerical model and the actual behavior of the samples. The difference between the laboratory and analytical results was less than 5%, indicating a good accuracy of the numerical modeling.

Keywords : reinforced concrete column steel jacket strengthening finite elements ansys axial load ductility