The Role of Chapter 24 Provisions in Reducing Seismic Vulnerability of Deteriorated Urban Fabric with Emphasis on Seismic Design Standard 2800; Case Study: District 4 of Tehran
The Role of Chapter 24 Provisions in Reducing Seismic Vulnerability of Deteriorated Urban Fabric with Emphasis on Seismic Design Standard 2800; Case Study: District 4 of Tehran
MohammadErfan Rezaei1 Nastaran Hassannataj2
1) M.Sc. Student in Urban Planning, University of Mazandaran, Babolsar, Iran -
2) M.Sc. in Bionic Architecture Technology, University of Mazandaran, Babolsar -
IOI Code
:
AACZ-ABGFFZ
Publication :
The 5th International Conference on Seismic Retrofitting(5icst.ir)
Abstract :
Deteriorated and inefficient urban fabrics, due to their physical characteristics such as fine-grained texture, impermeable street networks, and non-compliance with technical regulations, are highly vulnerable to natural hazards, particularly earthquakes. This study aims to evaluate the role of urban planning requirements stipulated in Chapter 24 of the National Building Regulations (Urban Compliance of Buildings) in conjunction with the novel approaches of the Fifth Edition of the Seismic Design Standard for Buildings (Standard 2800), in order to reduce the physical seismic vulnerability of deteriorated urban fabrics in District 4 of Tehran Metropolitan Area. District 4 of Tehran, as one of the most densely populated urban zones in proximity to active fault systems (including the North Tehran Fault and Mosha Fault), faces a severe mass-space non-compliance crisis in its deteriorated neighborhoods. The research methodology is quantitative-applied, in which physical-spatial indicators extracted from upstream planning documents, Chapter 24, and Appendices 6 and 11 of the Fifth Edition of Standard 2800 served as the evaluation framework. Key criteria including street width, enclosure index, building density, debris phenomenon, and fault setback zones were coded within a Geographic Information System (GIS) environment and weighted using the Analytic Hierarchy Process (AHP). The findings indicate that the application of physical compliance provisions of Chapter 24, particularly building height management proportional to street width, combined with the explicit requirements of Appendix 6 of Standard 2800 regarding the restraint of peripheral walls, can reduce the blockage rate of critical access routes during crisis conditions by up to 42%, thereby significantly enhancing the physical resilience of the deteriorated urban fabric in District 4.
Keywords : deteriorated urban fabric physical resilience chapter 24 of national building regulations standard 2800 district 4 of tehran