Design and Optimization of Coordinated Controllers for Reactive Power Compensation and Voltage Profile Enhancement in Sub-transmission Substations Using Advanced Algorithms: A Novel Approach Based on the Integration of Tap-Changing Transformers and Static Compensators
Design and Optimization of Coordinated Controllers for Reactive Power Compensation and Voltage Profile Enhancement in Sub-transmission Substations Using Advanced Algorithms: A Novel Approach Based on the Integration of Tap-Changing Transformers and Static Compensators
Javad pourhossein1 Ghasem Safaei Mehne2
1) Assistant Professor, Department of Electrical Engineering, Gonabad Branch, Islamic Azad University, Gonabad, Iran -
2) MSc Student, Department of Electrical Engineering, Gonabad Branch, Islamic Azad University, Gonabad, Iran -com
IOI Code
:
AAHD-ABGZFK
Publication :
National Conference on Information Technology, Nanotechnology, Artificial Intelligence and Technological Futures Studies(itnaf.ir)
Abstract :
One of the most fundamental challenges currently facing power industry operators is the simultaneous control of voltage and power factor in sub-transmission substations. Voltage control on the low-voltage side of transformers located in sub-transmission substations is performed by on-load tap changers (OLTCs) through sending tap reduction or increment commands via automatic voltage regulator (AVR) relays. Meanwhile, power factor and reactive power control on the low-voltage side is carried out by the switching of static sources and reactive power compensators that receive commands from var control relays. Currently, in sub-transmission substations, despite the mutual influence of voltage and reactive power variations on each other, there is no logical coordination between the AVR relay and the var control relay; consequently, optimal operation of sub-transmission substations cannot be achieved.
Hence, this paper proposes an optimal control approach for the simultaneous control of voltage and reactive power utilizing OLTC transformers and static reactive power sources. In this approach, a Genetic Algorithm (GA) simultaneously optimally tunes the controller coefficients of the transformer taps during voltage regulation and the controller coefficients of the static reactive power compensator during reactive power injection or absorption. This tuning is performed such that the objective function of the problem, namely the normalized sum of voltage deviation and the inverse of the power factor, is minimized. Consequently, the voltage profile and power factor in a sub-transmission substation are maintained within permissible and standard limits. The simulation results obtained in MATLAB software indicate an enhancement in the voltage profile and the regulation of the power factor within the standard limit of 1 per-unit (p.u.) in a 230/63 kV high-voltage substation. Therefore, as demonstrated in the simulations, the targeted objectives in the presence of the proposed optimal controller design exhibit highly significant improvements compared to the uncompensated state without the proposed controller.
Keywords : reactive power voltage profile sub transmission substation tap changing transformer