Is it possible to determine an appropriate angle for applying horizontal earthquake forces to a building, in accordance with the text of Standard 2800 (5th Edition)?

Is it possible to determine an appropriate angle for applying horizontal earthquake forces to a building, in accordance with the text of Standard 2800 (5th Edition)?

Shahin Mostaghaci1

1) Structural Designer, Supervisor, Executor, and Seismic Retrofit Specialist. M.Sc. in Civil Engineering (Structural Engineering), Shahid Madani University of Azerbaijan – Tabriz.

IOI Code : AAHE-ABGAKF
Publication : National Conference on Civil Engineering, Design and Construction Technologies, Energy, Materials and Advanced Machinery(icaeu.ir)
Abstract :
    In Standard 2800 (5th Edition), the section titled “Direction of Application of Earthquake Forces” is stated in a vague, ambiguous, and unclear manner, declaring that “the direction of application of the earthquake force shall be selected at an appropriate angle that produces, as far as possible, the most critical effect.” However, without explaining the method for determining this angle or whether reaching such an angle is even feasible, Standard 2800 replaces the determination of this angle with the so called 100–30 rule. In this article, an attempt has been made using simple yet comprehensive language to help the reader understand what an earthquake actually is and how it occurs. Why and how are data recorded from earthquakes in the form of ground motion acceleration? Why do the recorded ground acceleration data during an earthquake consist of three translational components two mutually perpendicular horizontal components and one vertical component? Why must a building be analyzed in two perpendicular directions under the effects of earthquake forces resulting from the horizontal components of ground acceleration, and why must its seismic adequacy be evaluated accordingly? What effect does the building plan configuration have on selecting the two principal, mutually perpendicular directions of the structure and on choosing an appropriate lateral load resisting system along those directions? How do architectural constraints and the architectural layout designed by the architect particularly those that cause irregularities in the lateral load resisting system affect the selection of the building’s two principal directions? Does the building response modification factor ® have any influence on determining the appropriate angle for applying horizontal earthquake forces to the structure? Considering all these questions and their answers, is it truly possible to determine an appropriate angle for applying horizontal earthquake forces to a building such that it produces, as far as possible, the most critical effect as stated in Iran’s Standard 2800? Furthermore, does the latest U.S. loading standard, ASCE7 22, address the issue of determining the appropriate angle for applying horizontal earthquake forces to a building in an equally vague and ambiguous manner?

Keywords : appropriate angle for applying horizontal earthquake forces the two principal directions of the building accelerograph (strong‑motion recorder) orthogonal direction combination method