Numerical Simulation of Fire Behavior in a Building Using PyroSim Software

Numerical Simulation of Fire Behavior in a Building Using PyroSim Software

Hamed Kazemi Esfanjani1 Alireza Eyvazzadeh Koljahi2 Reza Haji Mohammadi3

1) M.Sc. in HSE Engineering (Safety, Health, and Environmental Engineering), Faculty of Engineering, Ahar Branch, Islamic Azad University, Ahar, Iran.
2) Department of Chemical Engineering, Ahar Branch, Islamic Azad University, Ahar, Iran.
3) Department of Chemical Engineering, Ahar Branch, Islamic Azad University, Ahar, Iran.

IOI Code : AAHF-ABEAAE
Publication : National Conference on Architecture and Art Technologies, Smart City, Soft and Creative Industries and Technological Culture(icact.ir)
Abstract :
    Fire in buildings is one of the most dangerous and destructive incidents that can threaten the lives of occupants and cause extensive financial losses. Analyzing and predicting fire behavior in indoor environments is essential for designing safe buildings and developing preventive strategies. Due to the complexity of the physical and chemical processes involved in fire phenomena, experimental methods alone face significant limitations; therefore, numerical simulations using specialized software have become effective tools for accurately analyzing fire behavior. In this study, a fire scenario in a residential bedroom was simulated using PyroSim software, and the results were evaluated. Three different scenarios—including fire with natural ventilation, fire without window ventilation, and fire with a sprinkler system—were analyzed. The results indicate that in the natural ventilation scenario, the Heat Release Rate (HRR) reached approximately 9000 kW, and flashover occurred around 225 seconds, with temperatures exceeding 1000°C in the upper layers of the room. In the non-ventilated scenario, HRR was limited to 5000 kW, with incomplete combustion and a reduction of smoke layer height to 0.5 m. In the sprinkler scenario, the HRR was reduced to 600 kW, and the fire was suppressed in less than 30 seconds. Temperature–time graphs (for points at heights of 0.4, 1.0, 1.6, 2.2, and 2.8 meters) and temperature contours in cross-sections X = 2.2 and X = 3.4 illustrated the heat distribution and the influence of ventilation and sprinklers on fire behavior. Comparison with general fire development patterns shows consistency with typical thermal behavior, while ventilation intensity had a significant effect on HRR values. These findings can be used in designing and optimizing building safety and ventilation systems.

Keywords : numerical fire simulation pyrosim heat release rate flashover sprinkler system