Experimental Investigation of the Effect of Matric Suction on the Bearing Capacity of Strip Footings Adjacent to Unsaturated Sandy Slopes and Development of Design Charts
Experimental Investigation of the Effect of Matric Suction on the Bearing Capacity of Strip Footings Adjacent to Unsaturated Sandy Slopes and Development of Design Charts
Esmaeil Hashemi Mehr1 Bahram Nadi22 Meysam Bayat3 , Amir Taban4
1) Department of Civil Engineering, Na.C., Islamic Azad University, Najafabad, Iran
2) Department of Civil Engineering, Na.C., Islamic Azad University, Najafabad, Iran
3) Department of Civil Engineering, Na.C., Islamic Azad University, Najafabad, Iran
4) Department of Civil Engineering, Khorramabad Branch, Islamic Azad University, Khorramabad, Iran
IOI Code
:
ABFG-ACAAGD
Publication :
12th.international Congress on Civil Engineering, Architecture, Art and Urban Development(12icsau.ir)
Abstract :
Matric suction can influence the shear strength of unsaturated soils and, consequently, the bearing capacity of shallow foundations; however, the magnitude of this effect for footings located adjacent to slopes depends on the soil moisture conditions and the geometry of the problem. In this study, the effects of groundwater table depth, slope angle, and footing setback distance from the slope crest on the ultimate bearing capacity of strip footings on unsaturated Babolsar sand were investigated through 50 physical model tests. The tests were conducted for four slope angles (0°, 25°, 30°, and 35°), five groundwater table depths, and, for the inclined slopes, three normalized footing setback ratios (d/B). The soil-water characteristic curve (SWCC) was determined using the filter paper method and was employed to estimate the matric suction under the experimental conditions. The results showed that on level ground, the ultimate bearing capacity increased from 20.4 kPa to 130.8 kPa as the groundwater table depth increased from 0 to 500 mm. Furthermore, increasing the slope angle and decreasing the footing setback distance from the crest reduced the bearing capacity; specifically, at a groundwater table depth of 500 mm, the capacity reduction compared to level ground ranged from 46% to 68% at d/B=1, whereas this reduction was limited to 7% to 20% at d/B=4. Analysis of the bearing capacity ratio revealed a nonlinear trend with changing moisture conditions, where the rate of capacity increase gradually diminished at greater groundwater table depths. Finally, design charts were developed based on the experimental results to facilitate the estimation of bearing capacity within the investigated range of conditions. These charts can serve as a practical tool for evaluating the simultaneous effects of matric suction and slope geometry in the design of strip footings.