Design and Implementation of a Very Low-Energy Residential Building in Isfahan: An Integrated Approach to Thermal Envelope Optimization, Solar Energy Systems, and Greywater Recycling Case Study Subtitle: A Two-Story, Four-Unit Residential Building in Isfahan Classified as a Very Low-Energy Building (EC++
Design and Implementation of a Very Low-Energy Residential Building in Isfahan: An Integrated Approach to Thermal Envelope Optimization, Solar Energy Systems, and Greywater Recycling Case Study Subtitle: A Two-Story, Four-Unit Residential Building in Isfahan Classified as a Very Low-Energy Building (EC++
keihan Zarinnaghsh1
1) A Nationally Recognized Distinguished Figure in Management and Entrepreneurship
IOI Code
:
ABFG-ACAGZG
Publication :
12th.international Congress on Civil Engineering, Architecture, Art and Urban Development(12icsau.ir)
Abstract :
This article examines the design and construction of a highly energy-efficient, four-unit residential building in Isfahan, completed in 2024 (1405 SH). The project’s approach focuses on reducing energy demand through the enhancement of the thermal envelope, the selection of appropriate heating and cooling equipment, the utilization of solar energy, and the management of a portion of the building s water consumption. During the preliminary design phase, the details of the building envelope were developed based on calculations using the balance method and comprehensive building energy analysis. According to the project’s design and calculations, the installation of a 12 kW solar power system was sufficient to achieve the target classification of a highly energy-efficient building under the criteria of Section 19 of the National Building Regulations; however, due to a relatively small price difference, the capacity of the installed solar system was increased to 15 kW. Furthermore, a greywater treatment and recycling system with a capacity of 600 liters per day was incorporated during construction; the treated water is intended for use in toilet flushing systems and for cleaning the solar panels located on the roof. An economic analysis of the building envelope components indicates that the cost of implementing the insulated envelope was 29.3 billion Rials higher than that of a baseline (standard) envelope; conversely, the reduction in the cost of procuring heating and cooling equipment resulted in a capital saving of 7.67 billion Rials. Consequently, the net additional investment for this component amounts to 21.702 billion Rials; this figure offsets approximately 26% of the additional costs associated with the building envelope through savings on equipment procurement. Furthermore, accounting for the 17.420 billion Rials required to construct a solar power plant—necessary to achieve a very low-energy consumption building classification—the additional cost per square meter of construction is 30.37 million Rials (based on the period from February 2026 to July 2026). This paper relies on documentation regarding design, construction, and capital expenditures, rather than an analysis of energy monitoring results during the building s long-term operational phase
Keywords : low energy building thermal envelope balance method regulation 19 photovoltaics greywater economic analysis isfahan