Abstract :
Heatwaves combined with electricity outages can lead to rapid indoor overheating when mechanical cooling is unavailable. This study compares the preliminary thermal and cost performance of passive architectural interventions for a representative 120 m² apartment in Mashhad, Iran. A reduced-order, single-node thermal model was used to estimate indoor temperature from an energy balance involving envelope heat exchange, effective solar gains, and internal heat gains. The initial indoor temperature was set to 27 °C, effective thermal capacitance to 40 MJ/K, baseline effective heat-transfer coefficient to 500 W/K, and the analytical comparison threshold to 30.6 °C. Seven scenarios were evaluated: a baseline case, external shading, roof thermal improvement, window improvement, controlled air sealing, shading combined with roof improvement, and a combined shading–roof–window package. Under the assumed 24-hour outdoor-temperature stress profile, the baseline case crossed the threshold after approximately 4.78 h. The corresponding times were 6.09 h for external shading, 5.35 h for roof improvement, 5.68 h for window improvement, and 5.14 h for controlled air sealing. Combining shading and roof improvement extended the time to 7.61 h, while the combined shading–roof–window package extended it to 19.87 h. The latter value is calculated over the 24-hour profile; the indoor temperature remains below the threshold at hour 12. A simple comparison using assumed initial costs indicates that the option with the greatest thermal delay is not necessarily the least expensive per additional hour. The outdoor-temperature profile, thermal parameters, solar-gain values, and costs are scenario assumptions rather than measured building data or verified market quotations. The results should therefore be interpreted as a preliminary screening comparison, not as validated predictions for actual buildings.
Keywords : thermal resilience heatwave power outage passive architecture building envelope mashhad cost performance analysis