Investigation the effect of limestone powder replacing part of sand, diatomite powder replacing part of silica fume and ordinary sand instead of silica sand in reactive powder concrete and investigation their combined effects

Investigation the effect of limestone powder replacing part of sand, diatomite powder replacing part of silica fume and ordinary sand instead of silica sand in reactive powder concrete and investigation their combined effects

Javid Chakherlou1 Bahman Shervanitabar2

1) - Master of science-civil engineering, Azarbaijan Shahid Madani University, Tabriz, Iran,
2) Assistant Professor-civil engineering, Azarbaijan Shahid Madani University, Tabriz, Iran,

IOI Code : XACB-CGHAC
Publication : Conference on Civil Engineering, Architecture and Urabanism of the Islamic Countries(cau2018.ir)
Abstract :
    The result of research that has been carried out over the past few decades on new types of high performance concrete has been the flexible concrete known as Reactive Powder Concrete (RPC). This type of concrete is highly capable of concrete, which was registered in 1994 by a French construction company, one of the latest developments in the field of concrete, which eliminates many of the drawbacks to concrete. It is not economically feasible, but it is very useful in certain applications, and its pricing can be justified. In this research, according to the previous studies and experiments carried out in the Concrete Laboratory of Azarbaijan Shahid Madani University, the production of reactive powder concrete samples was carried out using limestone powder, diatomite powder and ordinary sand with local quartz powder. According to previous studies, the optimal percentage of materials replacement was 20% limestone powder instead of sand and 25% diatomite powder instead of silica fume, and replacement of ordinary sand passing through a sieve of 2.36 mm instead of 80% silica sand (instead of the total residue of silica sand) was obtained as the best replacement percentage in the mix design of this type of concrete and applied to the final mixing plan of the laboratory samples. Before pouring concrete into molds, the flow table test was conducted to control the concrete s workability and consistency, and concrete samples were made. After twenty four hours, concrete samples were removed from the molds and placed in the water at a temperature of 23 to 25 degrees Celsius. Compressive strength, water absorption during curing in 7, 28 and 90 days life has been tested. The results indicate that by replacing the materials mentioned above in this final mixing scheme, the highest compressive strength is obtained among the same workability samples. This final mixing plan has also been accompanied by increased water absorption during treatment.

Keywords : reactive powdered concrete diatomite powder limestone powder quartz powder compressive strength ordinary sand