Investigation of Parameters Effect on Direct Red Removal by Emulsion Fluid Membrane Using Experimental Design by Surface Response Method
Investigation of Parameters Effect on Direct Red Removal by Emulsion Fluid Membrane Using Experimental Design by Surface Response Method
fatemeh bahadouri1 maryam heydari2
1) engineer
2) doctor
IOI Code
:
XACK-CFDFH
Publication :
Second International Conference on Applied Sciences and Engineering Sciences, Shanghai, China(iasesconf.com)
Abstract :
In this paper, the direct red color was extracted using an emulsion liquid membrane from aqueous solution. Procedural-response method is a powerful tool for minimizing the number of tests. Due to the large number of effective variables and their interactions in this process and their optimization, the design of the test and the procedural-response method have been used to determine the minimum number of experiments. The materials used in this process include the carriers (butyl ammonium bromide), solvent (dichloromethane), the internal phase (ammonia) and the organic phase (spin 80, dichloromethane and butylated ammonium bromide). The variables studied in the process of color extraction with software include carrier roll, internal phase concentration, phase-to-phase ratio of membrane, and phase-to-feed ratio. A total of 29 experiments were performed using the Design Software and using the Box-Benck method. Optimum values were obtained for maximizing extraction. Experiments were also carried out to test the stability of the emulsion, including leakage, swelling and pruritus. To study the emulsion leakage, the variables studied included ammonia concentration, carrier concentration, internal phase to membrane phase and membrane phase to feed phase, to study the swelling of the carrier carrier variables and the phase-to-phase ratio of the membrane and for the irritation factor and color separation The effects of ammonia, sodium, and sodium carbonate were investigated as internal phase. The optimum conditions provided by the software for 0.001 M ammonia concentration, the carrier concentration are 0.02 g, the phase-to-phase ratio of the membrane is 0.9 and the membrane phase ratio to the feed phase is 0.7. In this case, the extraction rate is 98.18%. In general, the results of this study indicate that the process of emulsion liquid membrane is a suitable method for direct red color separation of 80.
Keywords : emulsion liquid membrane procedure response direct red color 80 extraction pruritus