Experimental and numerical study on two coaxial tube heat exchanger

Experimental and numerical study on two coaxial tube heat exchanger

Mehdi shojaei1 khashayar hosseinzadeh2 davood domairi ganji3

1) Department of Mechanical Engineering, Mazandaran Institute of Technology, Babol, Iran.
2) Department of Mechanical Engineering, babol noshirvani university of Technology, Babol, Iran
3) Department of Mechanical Engineering, babol noshirvani university of Technology, Babol, Iran

IOI Code : XAFE-CKDFF
Publication : 1st national conference in mechanical engineering(mechconf.com)
Abstract :
    In this study, heat transfer is investigated in a two-pipe converter of the center of water and water under the influence of various flow regimes (turbulent flow-calm). The device consists of two hot water reservoirs and cold water, where hot water is supplied by two heaters, as well as hot water and cold water by means of a flow meter (rutameter) and hot water in the inner tube (central) and cold water in the outer tube (External) flows, and then this cycle is repeated continuously. In this regard, numerical simulation is performed by Anys-Fluent software, and by changing the direction of cold water flow, current flow or current flow, and by changing the size of the flow of flow, the flow of calorific or mass flow occurs. And the efficiency of the device is checked in this case. In another section, using the numerical method, the effect of pipe use has been investigated. The results obtained in this study show that the heat transfer rate is both in the opposite direction and cold and hot water, and the thermal efficiency of the maximum converter is in the case of the opposite flow and calm water and the cold water is obscure. According to the results obtained in the converter with a simple tube, the flow rate from the calorific to the heat transfer disorder and the pressure drop are increased. This increase, depending on the flow regime of the tube side, has different results. The greatest increase in the heat transfer in cold stream is 2.5 times. In another section, the use of a twisted tube inside instead of a plain tube is paid. According to the results presented in this section, the use of twisted pipe in all models was accompanied by an increase in heat transfer, but the highest increase in heat transfer (34%) occurred in the case when the outer (cold) stream was encountered

Keywords : heat exchanger laminar flow turbulent flow heat transfer fluent numerical and experimental study