Evaluation of seismic response of reinforced concrete buildings designed in accordance with regulation height 2800 Fourth Edition of near-fault earthquake area
Evaluation of seismic response of reinforced concrete buildings designed in accordance with regulation height 2800 Fourth Edition of near-fault earthquake area
Mr. Seyed Ebrahim Mirzadeh Godarzi1 Ataallah Hajati Modaraei2
1) Master of Civil Engineering-Engineering, Bandar Anzali Unit, Islamic Azad University, Bandar Anzali, Iran
2) Faculty Member of Civil Engineering Department, Faculty of Engineering, Guilan University, Rasht, Iran
IOI Code
:
XBFA-DFFAE
Publication :
3rd International Conference on Applied Research in Structural Engineering and Construction Management(sharifsecm.ir)
Abstract :
Irregular buildings form the bulk of existing buildings in urban areas. One of the most common irregularities in urban structures is irregularity at altitude. In fact, by creating irregularities in buildings, the effect of the participation of higher motions is increased, and the response of the structure in various cases depends on the higher vibration periods of the higher motions. On the other hand, the main need for any resistance structure is needed to prevent early structural instability. Hardness is the second structure requirement against earthquake effects, which is the controller of destruction in non-corrosive components. Ductility is the third requirement of structures against severe earthquakes. Designs that are made according to the existing regulations are linear, while in the event of severe earthquakes, the structure enters the nonlinear region, so designing the systems with the assumption of linear behavior is not appropriate and the design issue Systems have been studied with nonlinear behavior. In this research, the main objective is to study the behavior of irregular reinforced concrete structures. To evaluate irregularities on RC structures, three types of three-dimensional models of 5, 10 and 20 floors, each floor, floor to floor, are 3 meters, and the dimensions of buildings are 30 × 30 m. The method of this work is that at first, the studied models were designed using the seismic design of Iran under ETABS software and then studied the seismic response by nonlinear dynamic analysis using SAP2000 software. The results of this study indicate that the regular presence of buildings improves the three factors of resistance, ductility and response modification according to nonlinear dynamic analysis.
Keywords : structural deformation nonlinear behavior of the structure regular rc structures irregular reinforced concrete structure nonlinear dynamics