Evaluating Response of Reinforced Concrete Structures Including Soft and Weak Story due to Blast Loading.
Evaluating Response of Reinforced Concrete Structures Including Soft and Weak Story due to Blast Loading.
Vahid Imani Garmehcheshmeh1 Houshyar Eimani Kalehsar2 Meysam Shirzadeh Garmi3
1) Graduate Student of Civil Engineering Structure - Higher Education Institute of Shahriyar Astara
2) PhD in Civil Engineering. Ardebil scholar
3) Ph.D. student of Civil Engineering, Ardebil University
IOI Code
:
XBFA-DFKDF
Publication :
3rd International Conference on Applied Research in Structural Engineering and Construction Management(sharifsecm.ir)
Abstract :
The extension of the use of concrete frame systems with a folding frame, in designed buildings and the vulnerability of these building systems to the explosion-induced loads has led to more concrete structures in Explosive loading loading is considered. In most seismic and explosive events, most of the mortalities and deaths were caused by the destruction of buildings, as compared to any other direct effect. Therefore, ensuring the stability and non-destruction of the building is primarily important, requiring a significant increase in the shape of the building. However, even if there are certain undesirable characteristics, even well-designed shaping structures also suffer from widespread damage. Public buildings, sales centers, banks, and so on. The structures are high in seismic zone and in type II land with 3 types of reinforced concrete frames with the number of floors 6, 8 and 10 having soft and poor floors (created by increasing height), 18 cases, modeling And analyzed and designed. And 20 meters in the Abaqus Limited Fibre Software. Nonlinear finite element analysis results show that the displacement of 6, 8, and 10 floor frames by the explosion of 2 tons will be 45 percent higher than the 1 ton explosion at similar intervals, and the stresses on the support will be similar in similar situations of 35 percent The frame, the stress entered into the recess and the destruction of the concrete, and by reducing the cost of explosives, and increasing the distance of the explosion from the frame, displacement, total tension entered into the frame, tone She has entered the ridge and the failure of the concrete has been reduced in concrete. According to the results obtained, concrete frames should be studied more for greater ductility against impact loads and explosive forces and with different methods, concrete frames for such incidents Retrofit and prepared to minimize the damage
Keywords : reinforced concrete buildings soft floor weak floor blast framing frame