Investigation of the displacement of the intake side of the restrained tubular tube with a curved buckling brace and without buckling of the buckling brace with the core of the reinforced concrete in buildings of 20 and 40 floors
Investigation of the displacement of the intake side of the restrained tubular tube with a curved buckling brace and without buckling of the buckling brace with the core of the reinforced concrete in buildings of 20 and 40 floors
hamid beirghi1 rasool mahbubi fuladi2
1) department of civil engineering. mahdishahr branch. islamic azad university. mahdishahr. iran
2) department of civil engineering. mahdishahr branch. islamic azad university. mahdishahr. iran
IOI Code
:
XBFA-DFZKK
Publication :
3rd International Conference on Applied Research in Structural Engineering and Construction Management(sharifsecm.ir)
Abstract :
Today, the traditional approach to designing buildings to provide adequate hardness and resistance has given way to a modern encounter with which energy absorption and loss of energy play a decisive role. The new methods, with the use of proper energy-dissipating materials in the structure, significantly reduce the material consumption in the structure and, in addition to the appropriate economic justification, improves the structural behavior and technical measures. Therefore, the use of steel structures with unbreakable braces seems very convenient. This paper incorporates a composite system of carbon-fiber tubular tubes and buckling braids, which has a very favorable effect in reducing the displacement of long steel structures.
In the bracing system, the ease of operation, the possibility of their reconstruction, easy repair and cost-effective repairs to flexural structures has always led designers to use this system. However, the most important disadvantages of this type of braid can be the weakness of the buckling of the compression member and its low ductility. For this reason, in the last three decades, research has been conducted to increase the uniformity of conventional braces, the most important of which is the new type of braid, referred to as archery bracelet. The buckling bracelet is a new seismic force system, which is more and more expanding due to efficiency and seismic performance better than conventional bracing. Therefore, in this paper, assuming this hybrid system with the number of floors of 20 and 40 floors, its behavior is examined in terms of relative relative displacement under actual earthquakes and reflection spectra of the design. The results show that the addition of a buckling brace to the steel frame system with concrete core has a favorable effect on the reduction of lateral displacement and relative relative displacement (in the 40-storey building, 50 percent reduction in lateral displacement is observed).