Investigation of Seismic Behavioral Behavior of Dipping and Ottoman Bars in Steel Structures Based on Solar Fenders in Tall Buildings

Investigation of Seismic Behavioral Behavior of Dipping and Ottoman Bars in Steel Structures Based on Solar Fenders in Tall Buildings

Darius Shadikhah1 Mehrdad Khaleqi Fard2

1) Master of Science (MSc), Civil Engineering Department, Yasuj Branch, Islamic Azad University, Yasuj, Iran
2) Department of Civil Engineering, Yasuj Branch, Islamic Azad University, Yasouj, Iran

IOI Code : XBFA-DGKZF
Publication : 3rd International Conference on Applied Research in Structural Engineering and Construction Management(sharifsecm.ir)
Abstract :
    Abstract: One of the most reliable seismic systems in steel structures is the convergent bracing system using oval and cross bar brackets, in which the hardness and resistance required can be provided with the least amount of steel for the structure, and the design and modeling with the least error Simply done. Crossbody and pendant bracing system as a supportive system in steel structures is one of the most common systems to withstand earthquake forces. The purpose of the present study was to investigate the effect of seismic behavior of inverted and pentagonal bars in steel structures based on candle fading in high-rise buildings. In order to investigate the seismic performance of 8 frames of 5 openings in classes 3, 5 and 7, it has been selected with two simple and rigid-to-column fittings. For this purpose, the ABAQUS finite element software software was modeled and analyzed for the seismic behavior of the steel structure. The results show that the restrained systems reduce the relative displacement values and the number of plastic joints in the structure during the earthquake and cause a uniform change in the relative displacement in the classes and in general, improve the seismic performance of the structure. In general, crossbar braces have caused more displacement by 45.8% compared to the vestibule braces in the structure. The highest horizontal displacement occurred at a rate of 3.166 in the short structure, with the least displacement related to the moderate structure, which occurred at 1.137, and in all types of braces, had a single behavior, and only the base cutting in the ventricular curtain It is more than a quill curtain and is 48.407. Key words: Seismic behavior, Inhibition of pivotal and occipital banding, Candle foundation, High-rise building.

Keywords : seismic behavior inhibition of pivotal and occipital banding candle foundation high rise building