Comparison and Comparison of Reinforced Concrete Buildings with Flexible Frame with Soft Floor and Non-Classy Flooring against Burden Damage
Comparison and Comparison of Reinforced Concrete Buildings with Flexible Frame with Soft Floor and Non-Classy Flooring against Burden Damage
Vahid Imani Garmehcheshmeh1 Houshyar Imani Kalehsar2 Meysam Shirzadeh Garmi3 Parvin Nonahal Gelandeh4
1) Graduate student of Structural Tendency, Higher Education Institute of Shahriyar Astara
2) PhD in Civil Engineering, associate professor at Ardebil Mohaghegh University
3) Ph.D. student of Civil Engineering, University of Mohaghegh Ardabili
4) Accounting expert, Azad University of Ardebil
IOI Code
:
XBHG-DKBEH
Publication :
2nd National Conference on Civil Engineering, Architecture and Urban Development of the Islamic World Countries(cau2019.ir)
Abstract :
Due to the events occurring in the corners of the world, the behavior of buildings under the influence of explosive loads due to different characteristics of this loading is not the same with other loads and considering the special position of concrete structures in the construction industry of the country and The extension of the use of concrete frame systems with a folding frame, in designed buildings and the vulnerability of these building systems to the explosion-induced loads has led to more concrete structures in Explosive loading loading is considered. In most seismic and explosive events, most of the mortalities and deaths were caused by the destruction of buildings, as compared to any other direct effect. Therefore, ensuring the stability and non-destruction of the building is primarily important, requiring a significant increase in the shape of the building. However, even if there are certain undesirable characteristics, even well-designed shaping structures also suffer from widespread damage. Therefore, it is necessary that the principles of earthquake and explosion resistant design on three different levels of structural, structural and shaping forms for all buildings, especially government buildings, such as offices, schools and hospitals, and Public buildings, sales centers, banks, and so on. The purpose of this study is to investigate the exact response of concrete structures of six, eight and ten floors with moderate bending frame with soft floor and soft floor, earthquake resistant under the influence of explosion loading. Since in this research it is assumed that these structures are high in seismic zone and in type II ground, with RC frame system with 6, 8, and 10 floors floors, without soft and weak floors and with floor Soft and weak (created by increasing altitude), a total of 36 cases were modeled and analyzed. These structures were designed for seismic forces and the critical structure of the structure for the simulation of the explosion was selected and subjected to the loads caused by the TNT explosion with weights of 1000 and 2000 kg and the spacing of the explosion site of the structure, 5, 10 And 20 meters in the Abaqus finite element software. The results of the analysis and design of structures show that the structures of soft and weak floors were reduced by 43% and structures displacement in structures with 6, 8 and 10 floors in structures of critical structure. Soft and weak floors at critical points relative to the non-smooth soft structure 65% and the side hardness of the soft and weak floors are relatively less than 70% less than the soft and weak floors in the critical points, as well as the displacement of the frames 6, 8 and 10 floors with TNT explosion of 2 tons with 5, 10 and 20 meters bombardment distances from the frame, compared to TNT explosion of 1 ton, 45 percent, total stress entered into 6-story frames at intervals of 5 , 10 And 20 meters TNT explosion of 2 tons compared to the explosion of 1 ton 9, 18, and 11 percent, in the 8-storey frame of 14, 17, and 18 percent, in 10-storey frames 15, 18, and 10 percent, and The tension entered into the ridge in 6-story frames at 5, 10 and 20 meters with a TNT of 2 tons compared to the explosion of 1 ton was 40, 35, and 25 percent respectively in 8, 40, 42 , And 32 percent in 10-story frames, respectively, are 29, 43, and 32 percent higher. In the following, the results of non-soft floor frames with soft and weak floors, all of which were at an altitude of one meter from the ground to the middle of the frame, and these frames, which were simulated against the load caused by the explosion load They were compared with each other, the results show that displacement, total stress entered the frame, and the tension entered into the support in soft-frame frames, is higher than the frames with a soft floor, as well as analysis and design Non-linear boundary components indicate that the location of connections (fountains of connections) and the middle of the frames are in critical condition at distances close to the event, and with the increase of the donkey The explosion, and the reduction of the distance of the explosion from the frame, the displacement, the total stresses on the frame, the stress entered into the support and the deterioration of the concrete, increased by reducing the cost of explosives, and increasing the distance of the explosion from the frame, displacement, total tension In the frame, the tension to the ridge and the failure of concrete in the concrete has been reduced. According to the results obtained, concrete frames should be studied more for greater ductility against impact loads and explosive forces and with different methods, concrete frames for such incidents Retrofit and prepared to minimize the damage.
Keywords : reinforced concrete buildings soft floors weak floors explosions bending frames