Investigation effect of Degree of Coupling on Steel Coupled Shear Wall

Investigation effect of Degree of Coupling on Steel Coupled Shear Wall

Farshid Ghasem zadeh1 hooman shokravi2

1) . Civil Engineering, Islamic Azad University, Lar branch, Shiraz, Iran, Email:
2) Structural Engineering, Islamic Azad University, Tabriz branch, Iran, Email:

IOI Code : XCZG-EDBGC
Publication : International Conference on Civil Engineering, Architecture , Development and Recreation Urban Infrastructure in Iran(icdu.ir)
Abstract :
    Steel shear walls are introduced as a lateral resistance systems to withstand seismic loads. Due to high buckling capacity, this system can tolerate seismic loads to a high level. In this study, the effect of the thickness of the shear wall, the length of the coupling beam and the flexural capacity of the coupling beam were studied theoretically and numerically. The degree of coupling is indeed the degree of involvement of the walls in the lateral bearing process. In addition, the effect of these parameters in different drift of coupling is investigated. Based on the results, the effect of flexural flexural strength is more effective in the behaviour of the coupled shear wall. The relationship between the flexural capacity of bond and coupling is nonlinear.

Keywords : coupling steel shear wall coupling degree coupling beam