Investigating the Effect of Heat Recovery Cycles to Increase Energy Efficiency Potential in ASU Freezer Air Separation Unit

Investigating the Effect of Heat Recovery Cycles to Increase Energy Efficiency Potential in ASU Freezer Air Separation Unit

hadi alimoradi1 alireza ajdani2 mahsa nazari3

1) Master, Professional Health Engineering, School of Health, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
2) Doctor of Medicine, Isfahan University of Medical Sciences, Iran
3) Master, Professional Health Engineering, School of Health, Shahid Sadoughi University of Medical Sciences, Yazd, Iran

IOI Code : XCZG-EFCBZ
Publication : International Conference on Civil Engineering, Architecture , Development and Recreation Urban Infrastructure in Iran(icdu.ir)
Abstract :
    Abstract In this paper, using modeling and simulation using Aspen Plus® v 8.1, the potential for improving energy efficiency of a conventional freezer air separation unit (ASU) was investigated. By converting heat from the compressor effluent to electricity, it is obtained using the organic rating cycle (ORC). Two different methods used to combine the compressor system and the ORC heat recovery with the conventional ASU freezer were used as the standard. This criterion is a worn-out ASU with 3 compression steps that uses water for suspension. In the first order, the water used as the coolant heat exchanger between the cooler / after a conventional worn-out ASU process is replaced by R134a, which also acts as the working fluid for the ORC (C3WHR) system, while in the case mode. Second, the 3-stage conventional process compressor is cooled with a single-stage compressor with the same overall compression ratio as the conventional process and the hot compressor output with R134a, which has also been replaced as the working fluid of the ORC system (C1WHR). Freezer-based simulation results are able to process 100 kg / s of atmospheric air at 30 C as the raw material, indicating that the specific power consumption for pure products for oxygen, nitrogen and argon is for oxygen, nitrogen and argon for Oxygen, nitrogen, and argon are reduced by adding a heat recovery system. C1WHR reduced specific power consumption by an average of 0.2 percent of the total net output, while C3WHR reduced it by an average of 11 percent. .

Keywords : modeling thermal cycle energy efficiency air separation (asu)