Evaluation of COHERENS Model in Effect of Thermal Sewage of Bandar Abbas Power Plant on Water Temperature Changes and Comparison with Field Data
Evaluation of COHERENS Model in Effect of Thermal Sewage of Bandar Abbas Power Plant on Water Temperature Changes and Comparison with Field Data
Milad Basirifard1 Masoumeh Behrouz2
1) Tehran University Email:
2) Shahid Beheshti University Email:
IOI Code
:
XDCZ-EHECG
Publication :
1st conference on engineering & innovation - University of Tabriz(ncoei.ir)
Abstract :
One of the applications of seawater is a source to cool the heat of power plant. If pollution enters these environments beyond their acceptance capacity, it can lead to many environmental problems.
Bandar Abbas Tavanir Power Plant is one of the industries that directly discharges its cooling water to the sea. Due to the special conditions of the Persian Gulf region, such as high salinity, low depth, high evaporation and semi-closure of the area, the ecosystem of this area has been in special conditions, which requires particular attention to contaminants including thermal pollution.
The model used to predict the thermal pollution of the Bandar Abbas power plant is COHERENS, a multipurpose 3D hydrodynamic model designed for coastal waters of the seas and continental shelves. The meteorological data in a 20-year statistical period, the main tidal components, the boundary conditions and the bathymetry data of the study area were used for model’s input data. After stabilizing and calibrating the model with measured temperature data, the simulation of the area for different seasons was performed for two years and the results were validated with existing field data.The results of the model show that the maximum water temperature of the studied area is about 32.6 °C in summer and the minimum water temperature is about 24.5 °C in winter. Modeling of Bandar Abbas power plant thermal pollution is done after model s sustainability. Comparing the results with field measurements showed the validity of the results of thermal pollution modeling. An increase of about ten degrees centigrade in the model of the wastewater discharge point indicates that the maximum temperature in the summer is about 41 degrees Celsius. Also, according to the results, the release of warm water in in fall season has a greater effect on the coastal waters of the Persian Gulf region.
Keywords : persian gulf coherens model bandar abbas power plant thermal pollution