The effect of the gap between the frame and masonry infille wall on the seismic response of reinforced concrete frames
The effect of the gap between the frame and masonry infille wall on the seismic response of reinforced concrete frames
Saeid Tayyebi1 Fariman Ranjbaran2 Somaih Karimiyan3
IOI Code
:
XDHH-GEKCB
Publication :
5th.International Conference & 6th.National Conference on Civil Engineering, Architecture, Art and Urban Design(5iccacs.ir)
Abstract :
Reinforced concrete frame (RC) filled with unreinforced building material (Infilled frame) is the most common seismic structure in many buildings around the world.
The seismic response of Infilled RC frames ( reinforced concrete frames ) is a function of the geometric properties of the frame and Infill wall materials , and the interaction between the two. The interaction between the frame and the masonry infille of the building materials is affected by the gap between the frame and the infill wall of the building materials.
This article is a study on the effect of the gap between the infille and the concrete frame with three different arrangements of the gap, the horizontal distance between the infill and the upper beam of the frame (Model 1), the vertical distance between the infill and the frame columns (Model 2) and the vertical and horizontal distance between the infill and Provides frame (model 3).
For this purpose, the finite element model of a three-story concrete frame infille (Infilled RC frames ) with and without gaps under the earthquake record in two orthogonal directions has been analyzed nonlinear dynamically. Seismic frame in model 1 out off plane destruction of masonry infille wall in the third floor has increased displacement and decreased base cut compared to the bare frame but less than the fully infilled frame (no gap). In model 2 due to no off-plate destruction of the frame And the increase in stiffness of the full roof displacement is greatly reduced and the base shear is also increased. (Model 2 acts like a fully infilled frame without gaps) Outside the frame, the secondary stiffness of the frame is reduced, thus increasing the displacement of the roof.
Keywords : in plane behavior out of plane behavior combined effect of in plane and off plane behavior gap between the frame and masonry infille wall seismic performance of concrete frame