The role of the type of establishment of apartment blocks in Ardabil city from the point of view of replacing the backyard with a patio pattern in the amount of energy consumption

The role of the type of establishment of apartment blocks in Ardabil city from the point of view of replacing the backyard with a patio pattern in the amount of energy consumption

Sina Pourezzati Hir1 Vahid Vaziri2

1) Graduate student at the Department of Architecture, University of Mohaghegh Ardabili, Ardabil,
2) Associate Professor at the Department of Architecture, Ardabil, Iran,

IOI Code : XGCA-KBBZB
Publication : 3rd.International Conference on Architecture, Civil Engineering, Urban Development, Environment and Horizons of Islamic Art in the Second Step Statement of the Revolution(3icacu.ir)
Abstract :
    Today, high energy consumption has become one of the most important human problems, and providing solutions to reduce energy consumption and sustainable development has become more important. Also, the construction sector accounts for a large part of energy consumption. Considering the critical situation of energy consumption in the construction industry in Iran with more than 40% energy consumption and an average consumption of 2.5 times compared to the global average, the use of renewable energy sources is very important to deal with the problem of excessive energy consumption. Solar energy is one of the most important renewable energy sources that can be used through active and passive systems. This research was conducted with the aim of investigating and comparing the use of the patio pattern as one of the passive solar systems compared to the backyard pattern in the types of apartment blocks in Ardabil city, considering the cold climate of the region. Design Builder software was used for simulation and energy calculations. According to the results, the heating load requirement of the northern building with a courtyard of 6792.78 kilowatt hours, the eastern building with a courtyard of 12216.38 kilowatt hours, and the western building with a courtyard of 10501.26 kilowatt hours was determined, while by replacing the patio pattern in the northern building, the heating load requirement It decreased to 2691.63 kWh, the eastern building to 8045.24 kWh and the western building to 6793.72 kWh. According to the analysis of the results, it was found that using the patio model is very effective in reducing the energy consumption of the building.

Keywords : patio north yard design builder ardabil city energy saving