Abstract :
    The unfavorable behavior of structures against earthquakes prompted researchers to consider other parameters in structural design. One of the parameters considered in the new approach of researchers to the behavior of structures is the concept of energy in structures. Reinforced concrete structures form a part of frame buildings and are among the most common buildings in our country. The use of such buildings has been widely used in our country since around 1330, but due to the lack of accurate design based on regulations. Related engineering, non-use of sustainable structure system and inappropriate constructions, most of the existing buildings can be classified as semi-resistant or non-resistant buildings. The existing buildings that were built in the last 30 years are considered as the most serious problem in the risk and vulnerability studies of our country, and according to the study of past earthquakes and the conditions of the country s buildings, a large number of the existing buildings are likely to be damaged and the studies Vulnerability also confirms this claim. Therefore, it is necessary to use fast and simple reliable methods for retrofitting existing buildings, and on this basis, it is of particular importance to compile and provide retrofitting methods that can be used for vulnerable buildings. The results of the analysis show that the formation of the soft floor, which is caused by the long length of the columns of the first floor compared to the other floors, or the hardness of the intermediate frames of the upper floors, can be very dangerous in the early failure of the structure and the formation of plastic joints at the base of the columns of the ground floor. Well done, the displacement curves of the first floor (hysteretic) and the displacement response history of the first and last floor have been investigated separately in each frame.

Keywords : earthquake vulnerability building damage concrete status building