Suitable features of double-shell facades to reduce energy consumption in cold and dry climates In order to provide an optimal model for high-rise buildings in Mashhad (Case example: Armitage Tower in Mashhad)

Suitable features of double-shell facades to reduce energy consumption in cold and dry climates In order to provide an optimal model for high-rise buildings in Mashhad (Case example: Armitage Tower in Mashhad)

Faranak Farhadi Nasab1 Fateme Mozaffari Ghadikollayi2 leyla Mirsaidi3

1) PhD student, Department of Architecture and Urban Planning, Faculty of Technical Engineering, Sari Branch, Islamic Azad University, Sari,
2) Assistant Professor, Department of Architecture and Urban Planning, Faculty of Engineering, Sari Branch, Islamic Azad University, Sari, Iran
3) Assistant Professor, Department of Architecture and Urban Planning, Faculty of Technical Engineering, Kavos Dome Branch, Islamic Azad University, Golestan, Iran

IOI Code : XGFB-KBHDD
Publication : 9th.International Congress On Civil Engineering, Architecture & Urban Development(9icsau.ir)
Abstract :
    Today, the energy crisis is one of the biggest concerns, especially in the field of building and architecture. Therefore, in order to investigate the function of the double-skin facade and its effect in the region of Mashhad, as well as to choose the appropriate option from among the four types of double-skin facades, in this research, at first, four A type of two-shell views (Box-window, Corridor, Shaft-Box, Multi-storey) from the point of view of energy in the climate of Mashhad, which is a cold and dry region. square meters in 17 floors on the ground floor, where the height of each floor is 5 meters, with an infrastructure of 84,567 square meters, with a southern view, which is completely glass and double skin, with a hole depth of 80 cm to 120 cm, with double-walled glass, which is rabies Opaque and transparent two-skin facades based on the source of ventilation of the space with different structures, which in the continuation of the proposed detail of each one with the air inlet and outlet dimensions of 0.6 meters are presented for analysis in order to optimize the analyzes that are performed. The best situation for the region Mashhad will be obtained and in the continuation of the wind speed and the temperature of the air flow in the view will be analyzed, and the findings and finally the result of this research will be presented. The multi-storey building has the best results for optimizing energy consumption in different seasons of the year. The results of the research showed that increasing the depth of the middle cavity of 120 cm can lead to the improvement of the thermal performance of the double-skin facade with an average thermal comfort of 21.9078. Also, the results show that the response of the double-glazed facade with a minimum cavity distance of 80 cm and opaque glass with maximum efficiency in the winter season with a maximum heating load of 12.135567 kwh and at least The required cooling load in the summer season is equivalent to 45.110487 kwh, as well as the comparison of the temperature and heat flux caused by the sun s radiation from the surface of the inner glass of the two skins in the cases with opaque or cloudy low emissivity glass with the middle hole width of 120 centimeters, the surface of the ventilation valve is 1.45 in total, the best type of performance It has natural ventilation with a rate of 38/75.

Keywords : optimizing energy consumption two shell facade cold and dry climate armitage tower shahr mashhad