Investigating the role of shade and entrance depth of traditional houses in providing thermal comfort, a case study: the historical context of Isfahan city
Investigating the role of shade and entrance depth of traditional houses in providing thermal comfort, a case study: the historical context of Isfahan city
Shadi Safarian1 Negar Zare2 Ramtin Mortaheb3
1) Master s student, Department of Architecture and Urban Planning, Technical and Engineering Faculty, Shahid Ashrafi Isfahani Non-Governmental University, Isfahan, Iran Email:
2) Master s student, Department of Architecture and Urban Planning, Technical and Engineering Faculty, Shahid Ashrafi Isfahani Non-Governmental University, Isfahan, Iran Email:
3) Assistant professor and faculty member, Department of Architecture and Urban Planning, Technical and Engineering Faculty, Shahid Ashrafi Isfahani Non-Governmental University, Isfahan, Iran Email:
IOI Code
:
XGFC-KBEGF
Publication :
8th.International Conference on Researches in Science & Engineering & 5th.International Congress on Civil, Architecture and Urbanism in Asia(8icrsie.com)
Abstract :
Entrance has various physical roles such as providing and monitoring internal and external communication, permeability, changeability, legibility and inviting. Based on research on the entrance of traditional buildings, the external thermal comfort factor of users has a decisive role. With the aim of providing more thermal comfort at the entrance of buildings, the present article has investigated the relationship of this parameter in the entrance of traditional houses of Isfahan with the help of shading techniques and the depth of the entrance. The front of these houses, with the help of the depth of the entrance, have performed the role of a horizontal canopy. In this way, the monthly average of the maximum angle of the sun s radiation with respect to the ground surface of Isfahan was measured, and the shadowing conditions at the entrance depth were predicted by calculating the monthly average of the shadow height. By comparing the results obtained from the average shade of the summer entrance, the height of the shade and the depth of the desired entrance were determined. In addition, the optimal entrance depth of Isfahan in the south direction was calculated as 0.5714 meters (equivalent to only 57 centimeters). Therefore, in determining the direction of dividing the land, or in choosing the direction of the entrance and designing the entrance and even its form, it is possible to take into account the points obtained from traditional architecture and the resulting formulas. Therefore, the depth, height, direction and amount of the desired shade for the incoming summer can be determined and suggested.
Keywords : climate design traditional architecture entrance shade thermal comfort