Technology change in pump plunger cover

Mohammad Gorji1 Mohammad Ali Sarfejo2

1) Graduated M.S. student, Islamc Azad University Fars, Lamerd Branch,
2) PhD student in engineering Metallurgy, Shiraz University of Technology

IOI Code : XHHA-KDKZH
Publication : 5th. International Congress On Engineering, Technology and Applied Sciences(etas2023.com)
Abstract :
    This research is focused on changing the coating technology of a high pressure pump plugger from an alumina ceramic structure to a Colmonoy 69 nickel base superalloy structure The coating applied on the AISI 316 L substrate is done by laser coating method and in preheated conditions up to 550 degrees Celsius. investigations of the improvement of crack growth resistance properties at the same time high wear resistance and flood properties. Hardness changes that indicate the wear resistance of the primary alumina coating in the range of 1529 to 2324 Vickers and for the Kolmono coating in the range of 69. It is 1350 to 1483 Vickers. Microscopic observations of the structure of Kolmonoi 69 indicate better crack growth resistance of the structure of Kolmonoi 69 compared to alumina, as well as the absence of crack propagation and small porosity in this sealing coating.By accepting a small amount of reduction in hardness and wear resistance with risk assessments, researchers have been able to increase the performance of the production plugger from one year of service to more than 3 years.

Keywords : kolmonoy 69 laser coating thermal spraying hardness microscopic structure plunger surface engineering