Investigating the benefits of using corrugated steel shear walls with different bearing patterns

Investigating the benefits of using corrugated steel shear walls with different bearing patterns

seyed ata seyed hatami1

1) Master of Science, Civil Engineering, Technical and Engineering Faculty, Islamic Azad University, Tabriz Branch, Tabriz, Iran

IOI Code : XKFK-AZHBAZ
Publication : 8th International Conference on Applied Researches in Science & Engineering (8carse.com)
Abstract :
    This article examines the benefits of using corrugated steel shear walls with different load bearing patterns in structural applications. This study focuses on analyzing the performance of these shear walls in terms of seismic resistance, bearing capacity and overall structural integrity. By examining various load-bearing patterns, including diagonal, chevron, and vertical arrangements, this research aims to provide insight into optimal design settings to maximize the benefits of corrugated steel shear walls in construction. Through comprehensive analyzes and simulations, this paper presents valuable findings that help to gain a deeper understanding of the benefits associated with the use of corrugated steel shear walls with specific load patterns, thereby informing future structural design practices. Since the idea of ​​achieving low yield stress in steel sheets with LYS materials is a bit far from reach and expensive, the idea of ​​using a perforated steel shear wall was formed, which can be a suitable alternative to achieve low yield stress in steel sheets. and optimization of boundary members. In fact, the main goal in perforated shear walls is to deliberately reduce the capacity of the sheet through the insertion of holes that are designed according to certain rules and regulations. 6 types of hole arrangement with a diameter of 120 mm are modeled. By corrugating the (horizontal) sheet, the final resistance has increased by 16%, and by corrugating the vertical sheet, the final resistance has increased by 18%. By creating a hole in the model of the wavy (horizontal) shear wall, it was observed that the final strength has decreased compared to the sample without holes. The plastic strain in the case of horizontal and vertical corrugated sheet has increased by 98% and 85%, respectively. By corrugating the shear wall sheet, the coefficient of behavior has increased compared to its traditional type, the largest increase is related to the horizontal corrugated steel shear wall, which has increased by 4%. By creating a hole in the horizontal corrugated shear wall model, the behavior coefficient of most models has decreased compared to the sample without holes. In fact, the main goal in perforated shear walls is to deliberately reduce the capacity of the sheet through the installation of holes that are designed with certain rules and regulations. The parameters of hole placement angle, hole diameter, hole spacing, hole arrangement type have an effect on the behavior of steel shear wall, and all these cases were investigated and evaluated in case of corrugated shear wall.

Keywords : corrugated steel shear wall cyclic load finite elements hole pattern