Evaluation of octagonal buckling bracing systems with zipper columns in the near and far field earthquakes
Evaluation of octagonal buckling bracing systems with zipper columns in the near and far field earthquakes
Mahmoud Goli1 reza rahmatzadeh2 tayebe seyyed sajadi moghadam3 seyyes mohammad hashemi mayvan4 shahin jenabi5 alireza bemani6
1) Master of Earthquake Engineering, Tehran, Iran
2) Master s student in Earthquake Engineering, University of Mohaghegh Ardabili, Ardabil, Iran
3) Bachelor of Civil Engineering, Islamic Azad University, Khoy Branch, West Azarbaijan, Iran
4) Master s student in Structural Engineering, University of Tehran, Tehran, Iran
5) Bachelor of Science in Civil Engineering, Hakim Sabzevari University, Sabzevar, Iran
6) Bachelor of Civil Engineering, Department of Civil Engineering, Mahrat National University, Tehran, Iran
IOI Code
:
XKHC-AZKGBA
Publication :
9th.International Conference on Researches in Science & Engineering & 6th.International Congress on Civil, Architecture and Urbanism in Asia(9icrsie.com)
Abstract :
Due to the increasing energy consumption in the world, the science of reinforcement is considered one of the most important sciences in the structural trends of civil engineering. This knowledge is a useful solution to prevent the waste of time, money, and energy for the continuous use of weak buildings. In the research conducted, considering the wide scope of application of the coaxial bracing system in our country, the reinforcement of buildings with this system was investigated using the idea of a stitched column. The use of a stitched column in systems with chevron (eight) bracing has caused the weakness of the chevron frame system, namely local buckling of beams and as a result, large displacements, to be reduced and the system experiences better stability. In order to comparatively evaluate the nonlinear dynamic analysis method, the time history and the effects of adding a stitched column to the chevron bracing system, the seismic behavior of three buildings of 5, 10, and 15 floors was studied under 3 earthquake records. And the results were examined in SAP2000 software. The results indicate the obvious weakness of the initial systems and the appropriate behavior of the reinforced buildings. Reducing plastic joints and floor displacement, improving performance levels, and increasing energy absorption and dissipation properties from earthquake forces are among the most important behavioral parameters improved after retrofitting in the buildings under investigation.
Keywords : stitched column time history analysis structural energy displacement buckling brace