Study of long height in beam section effect in two story special Concrete Moment Frame building by pushover analysis and FEMA P695 method

Study of long height in beam section effect in two story special Concrete Moment Frame building by pushover analysis and FEMA P695 method

Shahram mohammadpour1 Vahid Nazari2

1) Member of the Scientific Board of Islamic Azad University of azadshahr
2) Islamic Azad University of azadshahr teacher

IOI Code : XYBG-AZAEE
Publication : International Conference of Civil, Architecture and Urban Planning Elites(cau2016.com)
Abstract :
    It is a big problem to use long height in beam section at building while it is needed to consider weak beam and strong column rule in designing building to attain a suitable seismic behavior and ductility because this makes weak column versus beam and as a result plastic hinge occurs in column at first and redistribution of forces after first plastic hinge leads to make another hinge in other column which make mechanism in one story and finally structure fails for this weakness, in this situation two story building has two issues, at the first this structure often hasn’t strong beam error in first story but this error often occurs in second story so we don’t know how this condition influences on seismic factor of this kind of structure so this study tries to analysis this kind of structure by FEMA P695 method to attain seismic factor of it

Keywords : pushover analysis long height in beam section design factor fema p695