Comparison of alum, ferric chloride and lime in Kashans textile factories wastewater treatment with coagulation and flocculation method
Comparison of alum, ferric chloride and lime in Kashans textile factories wastewater treatment with coagulation and flocculation method
Borna Bahrami1 Parviz Monadjemi2
1) B. BAHRAMI, EDUCATED of CIVIL AND ENVIRONMENTAL ENGINEERING-SHIRAZ
2) P. MONADJEMI, Ph.D., ASSOCIATEPROF. Of CIVIL AND ENVIRONMENTAL ENGINEERING-SHIRAZ UNIVERSITY
IOI Code
:
XYCC-ABCFD
Publication :
International Conference on Science and Engineering(icesconf.com)
Abstract :
The effluent in textile industry generates too much contamination due to containing organic dye. In addition to this, water consumption in these industries is high. Therefore, the treatment of textile effluent prior to being released to the environment is essential. The most common methods of textile industry effluent treatment include chemical-physical coagulation and flocculation, adsorption, ozonation, reverse osmosis, using membrane filters and advanced oxidation each of which has its own merits and demerits. In this research, using aluminum sulfate Coagulants, ferric chloride and lime, the most appropriate coagulants under optimal conditions were used for the treatment of Kashan’s textile factories’ effluent through testing parameters like turbidity COD ، BOD5 and pH. In this study , pH which was used to select the optimal one was 4,5,6,7,8, and 9 .The bottom line was that using coagulation, the amount of dye ,turbidity, COD and BODS existing in textile industry effluent could be reduced significantly. Ferric chloride coagulant excelled lime or alum in terms of reducing turbidity and COD. The highest rate of COD and turbidity reduction by alum was 71% and 36% respectively, by ferric chloride, 71% and 85% and by lime 64% and 57%. The optimal pH for alum, ferric chloride and lime was 6,6,12 in turn.
Keywords : industrial effluent kashan’s textile factory effluent coagulants cod reduction