Determine the optimal time to Implementation and cool the joint study of its impact on the quality of concrete, bending and stretching test directly

Determine the optimal time to Implementation and cool the joint study of its impact on the quality of concrete, bending and stretching test directly

Seyedrahim BAHARAVAR1 Sima BAHARAVAR2 Nursultan KADİROF3

1) Doctorate in Civil Engineering, Civil Engineering-Materyal.Gazi University of Ankara
2) Master Architecture. Islamic Azad University of Tabriz
3) Doctorate in Civil Engineering, Civil Engineering-Materyal.Gazi University of Ankara

IOI Code : XYCE-ACFKA
Publication : International Conference on Civil Engineering, Architecture and urban infrastructure(icica.ir)
Abstract :
    This study investigated the effects of cold joints on the concrete tensile strength. In this study, according to TS EN 206-1 standard C25 class concrete was produced . 100 x 200 mm cylinder and prism of 100x100x500 mm in size to create a cold joint at 0 °, 45 ° and 90 ° poured concrete samples. After the casting of ½ of the samples, after 2, 3, 4 and 6 hours the second portion was poured. Direct tensile and flexural strength tests were performed on the obtained samples. According to the results, time increases in direct formation of cold joints are decreased tensile and flexural strength tests. This reduction was more clear at the concrete which poured after 6 hours.

Keywords : concrete cold joint direct tensile flexural strength