comparison of structural design result at the base of iranian standard no 2800 ver 4 and ASCE/SEI 7-10
comparison of structural design result at the base of iranian standard no 2800 ver 4 and ASCE/SEI 7-10
abbas parvin1 محمود سراجی2 محمد واقفی3
1) iran bushehr eslamic azad university email:
2) iran bushehr eslamic azad university email:
3) iran bushehr persian gulf university email:
IOI Code
:
XYCE-ADDHD
Publication :
International Conference on Civil Engineering, Architecture and urban infrastructure(icica.ir)
Abstract :
Standard no. 2800 as the main standard for design building against earthquake is very important.The fourth edition of this standard that was promulgated at the end of 2014 has a very changes with the past editions. The comparison of iran and america code can reval strengths and weaknesses and increased the knowledge of both regulations. This studay compared the design results of LRFD method by applying seismic criteria of the forth edition iranian standard no. 2800 with america ASE/SEI 7-10. For this purpose a three dimentional eccentic bracing frame with 5 & 8 stories, with the same stories hight 3 m, same span and same type of soil are put on under analysis and design. The result is that, structures has been designed according to ASE/SEI 7-10 america code has less drift, more base shear and more wight
Keywords : ebf drift displacement base shear