Evaluation of resistance of steel in the manufacture of steel shear panels

Evaluation of resistance of steel in the manufacture of steel shear panels

Mahsa Dehghani1 Hamidreza Ghezavati2

1) Islamic Azad University, Arsanjan branch, Iran Email:
2) Islamic Azad University, Arsanjan branch, Iran Email:

IOI Code : XYCZ-AAHFA
Publication : International Conference on Engineering and Applied Science(iceasconf.com)
Abstract :
    In this study we did Pushover analysis of some Steel Plate Shear Walls made of different strengths (from mild steel to the ordinary steel) with software and designed manually, and obtained the structural parameters. Also evaluate hysteresis behavior by the by finite element software ANSYS. Then repeat the procedure for panels made of Specific combination of steels with different strength as Hybrid steel. Results showed that the decrease of steel strength, increased some parameters such as structural ductility and reduction factor and improved hysteresis behavior and attract more energy absorption. Also by using Hybrid steel as infill plate of the steel plate shear walls, can put upon both of strength of construction steels and ductility of low yield strength steels together.

Keywords : steel plate shear wall mild steel hysteretic behavior ductility