condition monitoring of lubricating oil of V94.2 Siemens gas turbine (case study)

condition monitoring of lubricating oil of V94.2 Siemens gas turbine (case study)

seyedhashem moosavitabar1

1) University Lecturer, PSEEZ university of applied science and technology,

IOI Code : XYCZ-AAKEH
Publication : International Conference on Engineering and Applied Science(iceasconf.com)
Abstract :
    Nowadays condition monitoring method within the industrial equipment has substantially drawn attention of the society. In this method the tendency of the system changes are monitored during specific time periods. This would anticipate to control the trend of any changes in the system in order to prevent the occurrence of any damages to the system and consequently avoiding the machine from the “out of order” mode. In the current research the attempt is to investigate the monitor conditioning as a case study for the V94.2 siemens gas turbine from the lubrication point of view. In accordance with the manufacturer advice the operating condition of the turbine was examined for a period of 4000 hours. This was performed through taking samples from certain points of the machine. Then the samples were analysed via particle measurement method. This would help to identify the quality level of the oil. The quality of the oil would specify whether the system can still operate with the current oil or it requires to be changed. It was observed that by Purificating of turbine oil with respect to the outcome of the particle measurement, the operational condition of the machine becomes desirable.

Keywords : turbine condition monitoring oil analysis oil purification