Detection of Fault using microtremor data analysis
Detection of Fault using microtremor data analysis
Abdul Vahed Mirzakurdeh1 Marzieh Khalili2 Hossein Rahnema3
1) M.S.c Student in geology (tectonic) at the Shiraz University, Shiraz, Iran Email:
2) Assistant professor in the School of science at the Shiraz University, Shiraz, Iran Email:
3) Assistant professor in the School of Civil and Environmental Engineering at the Shiraz University of Technology, Shiraz, Iran Email:
IOI Code
:
XYCZ-ABZAB
Publication :
International Conference on Engineering and Applied Science(iceasconf.com)
Abstract :
According to the geological and structural position of Shiraz in the Zagros Folded Belt and numerous major and minor seismic faults in this region, identify the precise location of faults in relation to buildings are crucial. Since, the recognition and direct study of the faults takes a lot of time and costs, the microtremor methods, as one of the cheapest and easiest techniques used in the detection of hidden fracture. In this research, microtremor data measurement by H/V method in the study area have been done in 5 profile. Spectral ratio curves relate to each data obtained after smoothing and filtering; and by that means, predominant frequency and ratio gained. Also, vulnerability index calculated for each of stations. Ultimately, the results identified the fault location in the area.
Keywords : fault microtremor h/v method