behaviour of cfdst under axial and cycle load

behaviour of cfdst under axial and cycle load

soroush bazazi1 dr morteza naghi pour2

1) shomal university
2) shomal university

IOI Code : XYEA-AKKCG
Publication : The 4th International Congress On Civil Engineering, Architecture & Urban Development(4icsau.ir)
Abstract :
    Use of pipes which are filled with CFT concretes are developed during several recent decades, nowadays a developed type of CFT kinds that is called the double-walls steel pipes which are filled with CFDST concrete and these compound double-walls pillars are considered as the type of CFT pillars that consist of two steel walls with square or circle sections and are assembled in the concentric form and between its two walls are filled with concrete, they are considered because of their advantages in comparison with the initial CFTs. These advantages which are proved in various experiments are increase in section module, stability increase, lower weight, resistance against fire and …. . In spite of all attempts, there is little and limited information available about behavior of these pillars. In the present study the behavior of the new type of these pillars are considered using the method of limited components and using the ABAQUS software under the combined axial and cyclic load and with change in geometry of internal wall. To be assured of modeling the limited components the results obtained from numerical analysis of CFDST pillars are compared with available laboratory results.checks Suggest is to shift the inner geometry is better big impact will be on other parameters.

Keywords : compound double walls pillars latent bearing capacity form taking cyclic loading