Determination of protective distance of explosion for seismic designed reinforced concrete structures in different heights

Determination of protective distance of explosion for seismic designed reinforced concrete structures in different heights

soheil partovian1 Ghasem dehghani ashkezari2

1) student of M.Sc in Iran Azad University of Saveh Email:
2) Phd of Protective structures, faculty member of Iran Maleke Ashtar University

IOI Code : XYEA-BAECZ
Publication : The 4th International Congress On Civil Engineering, Architecture & Urban Development(4icsau.ir)
Abstract :
    Since Iran doesn’t have a comprehensive Code for designing explosive resistante structures, in this research will be explored that the structures which are designed with the Iranian 2800 Code, how much will stand the explosion loads; and besides, this amount of TNT should be located In which distance to support a specific performance level.The structure with a couple of different structural systems and different number of stories have been designed for earthquake forces. in addition, from the 4 types of soils in the 2800 standard, types 2 and 3 are adapted in this research. Also from the 4 standard earthquake regions, 2 earthquake regions (Severe and so severe seismic risk) are adapted. Besides, the structures are studied for 2 different number of stories containing 3 and 5 stories. The earthquake load is calculated with the equivalent static method. Due to the amount of the modes stated above, the number of designations of the structures with the ultimate strength method and static analysis had been 8 times. For exploring the above structures infront of explosive forces, 4 amount of TNT are adapted (100 kg, 500 kg, 1000 kg, 5000 kg). then each of the 8 structures, were nonlinear dynamically analysed for each amount of TNT in different distances of explosives from the structure and these analyses were done by the PERFORM-3D software; and the response of the structure was compared with the acceptance criteria of CP performance level.Then the distance of the explosives from the stucture has been increased until the responses of the structure have become lower than and near to acceptance criteria.The conclusion gained is that the (n) story building designed for earthquake forces of earthquake region (a) and in soil type (b), can resist (x) amount of TNT, in distance (d), for meeting the CP performance level acceptance criteria.

Keywords : explosion ultimate strength cp performance level distance of explosive height of structure