Comparison of blast and earthquake progressive collapse in buildings with steel bracing
Comparison of blast and earthquake progressive collapse in buildings with steel bracing
mohsen bahmani nia1 Abdolreza Sarvghad Moghadam2 ali Kheyroddin3 Seyyed Ahmad Hosseini4
1) MSc of Structural Engineering
2) Associate Professr ,Structural Engineering Research Center, International Institute of Earthquake Engineering and Seismolog,Tehran,Iran،
3) Professor ,Faculty Civil Engineering, Semnan University,Semnan,Iran
4) Assistant Professor, Faculty Civil Engineering, Malek Ashtar University of Technology ,Tehran,Iran
IOI Code
:
XYEA-BAGZC
Publication :
The 4th International Congress On Civil Engineering, Architecture & Urban Development(4icsau.ir)
Abstract :
Progressive collapse called as a kind of collapse that if each one of structures element delete structure don t have its freight continuation ability and to be collapse local or totality.the removal agents of structural elements that is discussed in this article, can be pointed to blast and earthquake. therefore three scaled earthquake with acceleration plan maximum 0.35 g for compare blast that creates base shear equal imperial valley earthquake applies to structures bracing. the results of blast with shear base equal earthquake less critical condition is shown the reason can be that continuity of blast was shorter. in this paper, four different type of brace is intended that during which structures bracing with Chevron 8 convergence with 4.8 cm displacement above the column deleted in blast and 6.1 cm in earthquake the worst and structures bracing with Chevron 7 divergent with 3.8 cm displacement in blast and 3.9 cm displacement in earthquake showed the best performance. plastic hinges control that as a criterion for comparing the performance of three-dimensional structures are, also confirms the accuracy of the results. in the continuation to check the height difference in the results 8 and 4-storey structures with bracing 8 diverging along with 12-storey structures compared that 4-story structures in the progressive collapse were collapse and the results 8-storey structures than 12-storey structures (8-storey structures in earthquake 26 and blast 8 hinge, 12-storey structures in blast and earthquakes 6 hinge) have been fewer safety, while the 12-storey structure into nonlinear LS area have not been .for comparison earthquake and blast of a factor (M), that the base shear the blast divided on earthquake, is used.
Keywords : progressive collapse bracing systems blast loading seismic loading