Assessment of behavior factor in Composite Steel Reinforced Concrete Wall

Assessment of behavior factor in Composite Steel Reinforced Concrete Wall

Amir Hooshang Akhaveissy1 Kambiz Daneshvar2 Morteza Amoei3

1) Associated Professor, Dept. of Civil Eng., Faculty Eng., RaziUniversity
2) Civil engineering graduate
3) Civil engineering graduate

IOI Code : XYEA-BZADF
Publication : The 4th International Congress On Civil Engineering, Architecture & Urban Development(4icsau.ir)
Abstract :
    For a long time, reinforced concrete shear walls are used in the building as lateral load resisting system. High-rise structures in high seismic zone may be face to some restrictions due to the high-value bars placed on the end of the wall. The use of Composite Steel Reinforced Concrete Wall (CSRCW) is a suitable alternative to this problem. In this research, the parameters such as ductility and behavior factor are studied by using various analyses performed on 12 samples of composite shear walls under cyclic loads. The sensitivity of behavior factor to type of platform (hard and soft platform) is investigated as part of this research. Samples analysis was performed by using the theoretical concepts of fiber and Opensees’s code.

Keywords : composite shear walls fiber method ductility behavior factor