Abstract :
    Instructions, criteria and technical seismic design standards of buildings have been amended continuously to maximize the absorption and amortization of seismic forces, improving performance level of structures according to their importance factor and minimize the Structural and nonstructural damage by considering the safety and economic Principles. This article presents a comparison of effective factors on calculation of seismic coefficient such as importance factor, spectral response, acceleration and building response modification factor on performance level of a concrete structure with Intermediate Moment-resisting Frame system by the nonlinear static analysis in SAP 2000 program stated in the second, third and fourth edition of Iranian Seismic Code (Standard NO. 2800), International Building Code (IBC) 2003 and Uniform Building Code (UBC) 1997. To perusal the effect of height, buildings have considered with three, five, seven and nine story. The results are compared with diagrams and tables.